A cantilever rack capacity chart lists three limits: how much each arm holds, how much each upright column holds, and the total for the bay. All three depend on arm length, upright height, the number of levels and how evenly the load sits on the arms. To size a rack, divide the load weight by the arms under it, then add every arm on the column and check both numbers against the manufacturer’s rating.
Key Takeaways
- Every cantilever rack has three limits: the arm rating, the upright rating, and the number of levels with its total load. Your load has to stay within all three.
- Longer arms hold less. In the Speedrack West stocked line, a 60 in arm is rated 2,000 lb and a 48 in x 4 in arm 2,600 lb.
- Load per arm = load weight / arms under it. Column load = the sum of the loads on every arm attached to that column.
- Ratings assume the load is centered and spread evenly. An off-center load can overload one arm even when the total is within the chart.
- Light, medium and heavy duty are labels, not ratings. Your real capacity comes from the load plaque or the manufacturer’s data for your exact configuration.
A new load shows up in the yard. The bundles are longer than last year’s, or heavier, or both. Someone asks whether the cantilever racks can take them, and nobody can find a number. The paperwork from the original install is gone, the arms have no labels, and the answer everyone falls back on is that the rack held the last load.
That guess is how arms get bent. A cantilever rack capacity chart doesn’t give you one number. It gives an arm rating, an upright rating and a limit on how many levels a column can carry, and your load has to fit within all three. Where the load sits on the arms changes the math too.
This guide gives you the capacity chart for the structural arms Speedrack West stocks, a five-step way to calculate what your rack carries, two worked examples, the placement rules that keep the ratings valid, what the 2025 edition of the cantilever rack standard changed, and where to find the real capacity of a rack you already own.
If you’re planning a new rack, you can check every number against your own setup in the Cantilever Rack Builder.
What does a cantilever rack capacity chart show?
A cantilever rack capacity chart lists the rated limit for each part of the rack that carries weight. Three limits matter, and each one is checked on its own.

What is arm capacity?
Arm capacity is the most load one arm can carry when the load is centered on it and spread evenly along it. The arm’s length and the size of its steel section set the rating. Among the structural cantilever arms Speedrack West stocks, the 48 in x 5 in arm is rated highest and the 60 in x 4 in arm lowest.
From our projects: For GTS Interior Supply in Beaverton, Oregon, Speedrack West installed single-sided structural cantilever racks, 16 feet tall with two arm levels, at a capacity of 2,000 lb per arm for their heavy loads. That is the rating chosen for that project, not a catalog figure.
What is upright capacity?
Upright capacity is the most combined load the arms on one column can put on it. Every arm on the column adds to it. Add a level and you add load to the cantilever uprights, even when each arm is well under its own rating.
What do the maximum levels and total load capacity mean?
The chart also gives the maximum number of arm levels for each arm size and the total load capacity for that setup. Heavier arms often allow fewer levels, because each level puts more weight on the same upright.
| Rating | What it limits | Where you find it |
|---|---|---|
| Arm capacity | The load on one arm | Capacity chart, load plaque, manufacturer data |
| Upright capacity | The combined load of all arms on one column | Capacity chart, load plaque, manufacturer data |
| Maximum levels and total load capacity | How many arm levels a column may carry, and the total load for that setup | Capacity chart, load plaque, LARC drawings |
Your load passes only if it stays within all three.
Cantilever rack capacity chart for Speedrack West structural arms
The chart below shows the ratings for the Speedrack West Cantilever Racking System.
| Rack configuration | Arm load capacity (lbs) | Max number of levels | Total load capacity (lbs) | Uprights load capacity (lbs) | Arm length (inches) |
|---|---|---|---|---|---|
| 48 in x 4 in arms | 2,600 | 4 | 10,400 | 11,600 | 48 |
| 48 in x 5 in arms | 3,000 | 3 | 9,000 | 11,600 | 48 |
| 60 in x 4 in arms | 2,000 | 5 | 10,000 | 11,600 | 60 |

How to read it:
- Total load capacity is the arm rating times the maximum number of levels: 2,600 lb x 4 levels = 10,400 lb.
- The 60 in arm is rated 600 lb less than the 48 in x 4 in arm, but it allows five levels.
- The 48 in x 5 in arm carries the most per arm, 3,000 lb, and allows three levels.
- All three configurations share the same upright rating: 11,600 lb.
Speedrack West stocks the uprights in 12 ft and 16 ft heights. These ratings apply to this product line only. Another manufacturer’s 48 in arm can carry a very different rating, so never apply one chart to another brand’s rack.
Why are light, medium and heavy duty labels not a capacity rating?
A duty label describes a product family, not a load limit. Light duty, medium duty, heavy duty and structural are broad product descriptions, not universal capacity ratings, and two systems with the same label can have different allowable loads.
Allowable capacity on cantilever racking changes with arm length, upright height, number of levels, bracing, component series and load distribution. The label tells you where to start looking. It doesn’t tell you what you can load.
| What a duty label tells you | What it doesn’t tell you |
|---|---|
| Roughly what weight class a product family is built for | The rated load of your arm at its length |
| A starting point for comparing product lines | How many levels your upright can carry |
| Nothing about your layout | Whether your configuration is within its limits |
How do you calculate cantilever rack capacity?

- Find the heaviest load for each level. Use the weight of the whole bundle or unit, including dunnage and banding, not a piece count.
- Divide it by the number of arms under it. That is the load per arm, assuming the load is centered and spread evenly.
- Add up the loads on every arm attached to one column. That is the column load. On a double-sided rack, both sides load the same column.
- Compare both numbers with the chart. The load per arm must stay within the arm rating. The column load must stay within the upright rating and the total for your number of levels. If any check fails, the configuration fails.
- Check the arm length. The arm has to support the full depth of the load, and the load can’t extend past the arm tip.
Worked example 1: how much does each arm carry?

The Rack Manufacturers Institute (RMI) uses this example in its guidance on uniform load placement on cantilever racks: a load 180 inches long that weighs 3,000 lb, resting on three arms spaced 60 inches apart. Each arm carries 1,000 lb.
To keep the load balanced, the operator places it so it overhangs the two outer arms by 30 inches at each end. That overhang is half the column center-to-center spacing.
Worked example 2: how much does the column carry?
Now use the chart. Say you store steel bundles that weigh 6,000 lb each on a single-sided rack with three uprights and 48 in x 4 in arms, four levels high. Each level rests on three arms, one per upright.
| Step | Calculation | Result | Check against the chart |
|---|---|---|---|
| Load per arm | 6,000 lb / 3 arms | 2,000 lb | Within the 2,600 lb arm rating: pass |
| Load on each column | 4 levels x 2,000 lb | 8,000 lb | Within 10,400 lb total and 11,600 lb upright: pass |
| Add a fifth level | 5 levels on 48 in x 4 in arms | Not allowed | Maximum is 4 levels: fail |
| Heavier 8,400 lb bundles | 8,400 lb / 3 arms | 2,800 lb per arm | Over the 2,600 lb arm rating: fail |
| Switch to 48 in x 5 in arms, 3 levels | 3 levels x 2,800 lb | 8,400 lb per column | Within 3,000 lb per arm and 9,000 lb total: pass |
The heavier bundles fit, but only on the heavier arm and with one fewer level. That’s the tradeoff the chart shows, and it’s why you size the rack for the heaviest load you expect, not the average one.
How does load placement change capacity?
Every number in a capacity chart assumes the load sits where the rack was designed for it to sit. RMI quotes ANSI MH16.3 on this point: in the absence of other information, arms are designed for loads that are symmetrically placed and evenly distributed, both along the rack and from the tip to the rear of the arm. Move the load and the ratings stop applying.

Why must the load be centered side to side?
If the load is off-center along the rack, the arm at the heavy end carries more than its share. It can be overloaded even when the total weight is within the chart. RMI calls for uniform, symmetric placement across the arms, and the 2025 edition of the standard added figures showing how off-center loading raises arm forces. Train operators to recenter any load that hangs too far to one side.
How far out on the arm can the load sit?
The arm must support the full depth of the load, the load can’t extend past the arm tip, and the center of the load must not sit past the center of the arm toward the aisle. The farther out the load sits, the more the arm bends. Place loads as close to the column as you can.
For round loads such as pipe and tubing, inclined arms help. On the Speedrack West line, straight arms up to 48 in long have a minimum pitch of 3/8 in per foot to make up for deflection, and inclined arms have a 20 degree pitch. Compare straight and inclined arm types before you choose.
How far apart should cantilever arms be?
In the RMI example, overhang is half the column spacing, so 60 inch spacing means 30 inches of overhang at each end. Speedrack West cantilever bracing comes in 48 in, 60 in and 72 in upright spacing.
Flexible loads such as pipe, tubing and thin lumber sag between supports and may need more arms. RMI notes that long loads often sag under their own weight while they’re placed or removed. For spacing math on your own load, use our cantilever rack installation checklist.
What changed in the 2025 cantilever rack standard (ANSI MH16.3-2025)?
RMI publishes ANSI MH16.3, the American standard for the design, testing and use of industrial steel cantilever racks. The first edition came out in 2016. RMI announced the revised MH16.3-2025 in January 2026. These are the changes that matter most for capacity:
| Change in MH16.3-2025 | What it means for you |
|---|---|
| New product load section, with figures comparing centered and off-center loads, the resulting arm forces, and equations for loading tolerance | Off-center loading is now addressed directly. Operators should recenter loads that hang to one side. |
| An explicit arm deflection limit. The earlier edition only required that arms not deflect below horizontal. | New designs have a firm limit on how far arms may bend under load. |
| Updated method for combining pallet, seismic and snow loads | Outdoor racks and racks in earthquake areas are designed with current structural methods. |
| Clearer post-installation inspection: the engineer of record notes what must be inspected | Ask for the list of required inspections before the rack goes into use. |
| Direct analysis method for seismic and stability checks, as used for selective pallet rack | Column stability is checked with a more accurate method. |
MH16.3 is a paid standard, and the summary above comes from RMI’s announcement. Outdoor racks and racks in seismic areas need site-specific design, which is why Speedrack West offers seismic calculations and handles rack permits.
From our projects: For Levi’s Sawmill in La Pine, Oregon, Speedrack West supplied structural cantilever racks, single- and double-sided, with 4 arms per column, designed for a maximum seismic uniform arm load of 1,500 lb per arm. That rating came from the project’s seismic design, not a catalog chart.
Where do you find the real capacity of an existing cantilever rack?
A chart tells you what a product line is rated for. The rack in your yard is rated by its own design documents.
| Document | What it shows | Who issues it |
|---|---|---|
| Load capacity plaque | The rated loads and configuration, posted where operators can see them | The rack manufacturer, or the owner has plaques made |
| LARC drawings | The arm configurations and load capacities the system’s components can safely support | The manufacturer or a qualified rack design engineer |
| R-Mark certification | That the whole system was engineered and reviewed to MH16.3 for that specific site | The manufacturer only, shown on the LARC drawings or plaques |
| Manufacturer data | The rating of each component at its dimensions | The manufacturer |
What is on a load capacity plaque?
For pallet rack, RMI lists what a plaque must show under ANSI MH16.1 Section 4.5: the maximum unit load or load per level, the maximum total load per bay, and the number and spacing of levels, and that a plaque should measure at least 50 square inches. You can read the details in RMI’s article on why load capacity plaques matter.
For cantilever racks, RMI says significant changes to the configuration that alter load capacities require updated plaques. Our warehouse rack labeling guide covers where to post them.
What is a LARC drawing?
LARC stands for load application and rack configuration. The drawings show the arm configurations and load capacities the components can safely support. Before you store a new load type or move arms, RMI says to check the LARC drawings first and consult the original manufacturer or a qualified rack design engineer if the change isn’t shown.
Is my cantilever rack R-Mark certified?
Only if the system was certified as a whole. RMI’s R-Mark program for cantilever racks covers a complete system engineered for one project site, not a single upright, arm or base. The only way to confirm it is the R-Mark logo and certification number on the LARC drawings or load capacity plaques from the manufacturer.
What if there is no plaque or paperwork?
Used and inherited racks often arrive without paperwork. Identify the manufacturer, ask them for the rating of your exact configuration, or have a qualified engineer evaluate the rack. Don’t borrow numbers from a chart for a different product line. Our guide to used cantilever racks covers what to check before you buy one.
RMI recommends inspecting cantilever racks at least once a year, and more often for damaged racks or racks in high-traffic areas. A rack safety inspection gives you a written record of the rack’s condition.
OSHA doesn’t publish a capacity number for cantilever racks. Its general rule, 29 CFR 1910.176(b), says storage must not create a hazard and that bundles stored in tiers must be stable and secure against sliding or collapse.
FAQs
How much weight can a cantilever rack hold?
It depends on the arm, the upright and the number of levels. In the Speedrack West stocked structural line, arms are rated 2,000 to 3,000 lb each and one upright is rated 11,600 lb. The total load capacity per configuration runs from 9,000 to 10,400 lb, depending on the arm and the number of levels.
How much weight can a cantilever arm support?
The rating depends on the arm’s length and steel section. In the Speedrack West stocked line, the 48 in x 4 in arm is rated 2,600 lb, the 48 in x 5 in arm 3,000 lb and the 60 in x 4 in arm 2,000 lb. Those ratings assume the load is centered and spread evenly.
How do you calculate rack load capacity?
Divide the weight of each level’s load by the number of arms under it to get the load per arm. Add the loads on every arm attached to one upright to get the column load. Both numbers must stay within the manufacturer’s arm and upright ratings for your number of levels.
How many pounds can a cantilever rack hold per level?
One level can hold the arm rating times the number of arms under the load, as long as the load is centered and the column totals stay within the chart. Three 48 in x 4 in arms rated 2,600 lb each carry up to 7,800 lb on one level.
Size it for the heaviest load
A cantilever rack capacity chart only works when you read all of it. Check the arm rating, the upright rating and the level limit, and keep the load within all three. Do the math per arm, then per column. Then keep the load centered and close to the column, because every rating assumes it is.
Planning a new rack? Configure it in the rack builder to see the rated parts and price for your setup, or start with our guide to choosing a cantilever rack.
If your load doesn’t fit the chart, or you’re not sure what an existing rack is rated for, send your load details (length, weight and count) or call 503-640-5666, and we’ll work out the layout with you.
Was this helpful?